Z1 Ignition circuit - burning fuse wire

#1 PostAuthor: malmojoe » Fri Sep 26, 2014 1:58 pm

Hello, I have a new loom. Only have a new ignition switch and a new RH switch plugged in, so the bare minimum. As soon as I connect up the coils, the fuse wire starts cooking. Any ideas what is wrong?

Thanks for any help.

User avatar
z1bman
Hardcore
Hardcore
Posts: 4227
Joined: 3rd Mar 2010
Location: WORDSLEY WEST MIDLANDS

#2 PostAuthor: z1bman » Fri Sep 26, 2014 4:03 pm

what size is the fuse? try fitting one coil at a time

User avatar
Mark Tiller
Area Rep.
Area Rep.
Posts: 1772
Joined: 12th Jun 2011
Location: Stewkley, Leighton Buzzard

#3 PostAuthor: Mark Tiller » Fri Sep 26, 2014 4:23 pm

check all bullets....sounds like a dead short

malmojoe

#4 PostAuthor: malmojoe » Fri Sep 26, 2014 4:57 pm

Using a 30a fuse, only other ones I have are 10 amp and blow
I have nothing plugged in except the ign and RH switch so no bullets.
Removing the rectifier and regulator from the circuit, and holding the white fuse wire onto the white feed wire, with both coils disconnected - no problem. No earthing, press starter - all good. If I touch the coil feed wire (yellow/red) with the coil wires, the coil with the closed points arcs and connecting it starts the fuse wire heating up.
Just to check the earths: battery earth cable is connected to engine, as is the earth from the regulator and the yellow/black wire from the loom.


Have checked the rectifier - OK
starter relay works and checks out (should there be continuity between black and yellow/black wires?)

User avatar
z1bman
Hardcore
Hardcore
Posts: 4227
Joined: 3rd Mar 2010
Location: WORDSLEY WEST MIDLANDS

#5 PostAuthor: z1bman » Fri Sep 26, 2014 5:08 pm

max fuse should be 20 amp sounds like a coil has shorted internally. have you left the ignition on for more than five minutes or so ? have you got the points wires insulated with the fibre washers

malmojoe

#6 PostAuthor: malmojoe » Fri Sep 26, 2014 5:31 pm

Thanks for your help both, I'll have a look tomorrow. Change the coils and check the points. None of which I fitted and both of which look a bit cheap and nasty. I'll have a look at the manual tonight too.

User avatar
ZedHead
Hardcore
Hardcore
Posts: 1950
Joined: 9th May 2009
Location: North Yorkshire
Contact:

#7 PostAuthor: ZedHead » Fri Sep 26, 2014 8:46 pm

Definitely sounds like a shorted coil