main fuse

#1 PostAuthor: geraldknight » Sun May 11, 2014 2:29 pm

hi could anyone help please. I have a Z1b that has been imported & stood up for about 3 years. Ive tidied the bike up & looks very nice but i have a problem. When you start the bike after about 3 minutes of running in neutral or riding the bike about 5 to 10 minutes the main 20A fuse blows. Its done it several times now. Ive changed the regulator & rectifier from my other z1b & the fault still occurs. With a clamp on ammeter that is calibrated the current drawn is no higher than 6 to 7 amps. Any help pls would to be great. regards gerald

User avatar
PAULJAC47
Hardcore
Hardcore
Posts: 3266
Joined: 31st Aug 2008
Location: WOLVO WEST MIDS ENGLAND

#2 PostAuthor: PAULJAC47 » Sun May 11, 2014 4:00 pm

HI Gerald, sounds like a short to me connect a 12volts lamp in parallel with the 20amp fuse this should indicate when the short occurs ie it will glow brighter,it may be case of isolating circuits to find the fault favourites are the loom to the bars,cut out switch but of course it could be anywhere as the B only has this one fuse and has no segregation for separate circuits..Good Luck Paul J
PAULJAC47,,,,,"She may not look like much, but she's got it where it counts, kid."
-Han Solo

You can't polish a turd, but you can roll it in glitter

Salad is what real food eats.
Anon

PUM 673

User avatar
steve bowdler
Area Rep.
Area Rep.
Posts: 1793
Joined: 20th Apr 2005
Location: swansea s.wales

#3 PostAuthor: steve bowdler » Sun May 11, 2014 6:06 pm

Some have replaced the fuse with one of these

http://www.ebay.co.uk/itm/260697711758? ... EBIDX%3AIT

I have chenged to blade fuses lot better than the older style fuses

User avatar
ZedHead
Hardcore
Hardcore
Posts: 1950
Joined: 9th May 2009
Location: North Yorkshire
Contact:

#4 PostAuthor: ZedHead » Sun May 11, 2014 7:54 pm

Inspect the blown fuse if it is heavily blackened or shattered you are looking for an intermittent dead short, which you will only find though a process of elimination. A lightly blown fuse indicates a slight overload. I have had problems with the poor contact in the fuse holder causing it to overheat. This in itself could be enough to melt the fuse.

I would fit the relay mod as a matter of course

geraldknight
Regular Poster
Posts: 54
Joined: 6th Oct 2009
Location: exeter

main fuse blowing

#5 PostAuthor: geraldknight » Sat May 17, 2014 5:15 pm

Hi thanks for your help to all who replied. I found a short on the loom to the right hand switch. I think ive sorted it because it seems ok now & just had it mot ed. Now to register it & ride it this summer. Thanks again for your help. :D